Model Number: Aluwedo-C-061
Brand Name: ALUWEDO
Key Specifications/Special Features:
According to the non-combustibility (grade a composite core) stipulations of GB8624-1997, the A2 ACP has passed tests of National Center for Quality Supervision and Testing of Fireproof Building Materials.Certification:CS, UL, SGS, SII, ISO 14001, ISO09001, OHSAS18001, REACH, ROHSPanel SpecificationsThickness:2mm (0.08”), 3mm ( 0.12”) 4mm (0.16”) 5mm (0.2”) 6mm (0.24”) ,
Thickness recommended: 4mm( 0.16”)
Width: 850mm to 2000mm, ( 34” to 80” )
Recommended: 1220mm (48.8”), 1250mm (50”), 1500mm(60”), 2000mm(80”)
Panel length as required
Aluminum thickness: 0.3mm (0.012”) to 0.5mm (0.02”)
*Custom width and length available upon request subject to minimum quantities
1220mm (4ft)*2440mm (8ft)*3mm (0.12”)*0.21mm (0.08”)
1500mm (5ft)*3050mm (10ft)*3mm (0.12”)*0.21mm (0.08”)
-Light weight, high strength, extreme rigidity, superior impact resistance,
-excellent surface flatness and smoothness ,
-heat insulation, sound insulation, fire-resistance,
-acid-resistance, alkali-resistance, good weatherproofing and non-resonance
-various uniform colors ,can be easily processed and fabricated, quickly installed,
-elegant and magnificent, good flexibility fits various designs,
-easily maintenance, simply cleaning
-Constructional exterior curtain walls;
-Decorative renovation for storey-added old buildings;
-Indoors decoration for interior walls, ceilings, bathrooms, kitchens and balconies;
-Advertisement board, display platforms and signboards;
-Wallboard and ceilings for tunnels;
-Raw materials in industrial purpose;
-Materials used for vehicle and boat.
-
Package:wooden pallets fumigated
NO. |
Test Items |
Test Methods |
Technical Indexes |
Results |
Conclusions |
1 |
Mini length of remains, mm |
GB/T 8625-88 |
0 |
575 |
Qualified |
2 |
Average length of remains, mm |
GB/T 8625-88 |
0 |
614 |
Qualified |
3 |
Average Temperature of smoke , td> |
GB/T 8625-88 |
5 |
106 |
Qualified |
4 |
Grade of Smoke Density |
GB/T 8627-1999 |
|
7 |
Qualified |
5 |
Heat, MJ/Kg |
GB/T 14402-93 |
2 |
0.2 |
Qualified |
6 |
Release of Heat, MJ/td> |
GB/T 14402-93 |
.8 |
0.05 |
Qualified |
7 |
Toxicity of Smoke and Gas(LCo), Mg/L |
GA 132-1996 |
.0, during infectious period, the rat doesn’t die. Within 3 days from getting infected, the rat not only lives, but also recovers in weight |
25 |
Qualified |